Options
| Step 4 - Select Memory
Options |
| Memory Configuration Guidelines |
Memory options should be selected in the
context of the application's sensitivity to memory bandwidth and future memory expansion.
This will determine the number of memory options to order. The total capacity required
will determine the size of the options to be ordered.
Mandatory selection of at least two memory options per CPU Building Block Module
ordered in Step 3.
- Each GS1280 Model 8 system can support up to 16 memory options (four RIMMs each) and up
to 16 memory RAID options (one RIMM each) for a total of 80 RIMMs when configured with 8
CPUs.
- Each GS1280 Model 16 system can support up to 32 memory options and up to 32 memory RAID
options for a total of 160 RIMMs when configured with 16 CPUs.
- The total number of memory options installed must equal or exceed the number of I/O
Expansion Drawers ordered in Step 6; i.e., each CPU connected to an I/O Drawer must contain
memory in at least one memory controller.
- Each CPU has two memory controllers - Each memory controller
can support four RIMMs (one memory option) and a fifth RIMM slot for redundancy (RAID
option).
- If populated, the two memory controllers per CPU must contain the same size RIMMs.
- Order one RAID option (one RIMM) per memory option if desired.
- If RAID memory is selected, the number of RAID options must equal the number of
memory options selected.
The following examples illustrate different ways of configuring a GS1280 Model 8 with
four CPUs with a total of 4-GB of memory. |
| |
|
CPU
Building Block Module #1 |
CPU
Building Block Module #2 |
| Case |
Memory Option |
CPU
1 |
CPU
2 |
CPU
3 |
CPU
4 |
| Controller 1 |
Controller 2 |
Controller 1 |
Controller 2 |
Controller 1 |
Controller 2 |
Controller 1 |
Controller 2 |
| A |
3X-MS7AB-AA (4x128 MB) |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
1 |
| B |
3X-MS7AB-BA (4x256
MB) |
1 |
- |
1 |
- |
1 |
- |
1 |
- |
| |
| Memory Application Examples |
| Configuring memory is a
compromise between cost, total memory capacity, and memory bandwidth requirements. The
behavior of the application must be used to define the most-desired configuration. Some
applications are sensitive to memory capacity, some are sensitive to memory bandwidth,
some are sensitive to neither. If actual application measurements are not available, the
following may be used as guidelines: |
- Large memory (VLM) applications, in which large amounts of memory can substantially
reduce I/O throughput, may be optimized for total memory capacity and future capacity
growth. In VLM applications, the right balance might be one memory option per CPU. (Case
B)
- Typical commercial applications, such as transaction processing (OLTP) and multi-user
timesharing, usually operate efficiently from cache and may not be materially affected by
memory bandwidth. Memory configuration is a balance between memory bandwidth and future
capacity growth. It is advisable to match the number of options to the number of CPUs.
(Case B)
- Data mining can benefit from additional memory bandwidth. It is best to match the number
of memory base modules to the number of CPUs. (Case A)
- The most demanding high-performance technical applications (HPTC) achieve a performance
level that is directly proportional to memory bandwidth. In these cases, configure two
memory options per CPU. (Case A)
|
|
512-MB RDRAM Memory (4x128)
Option |
3X-MS7AB-AA |
|
512-MB RDRAM Memory (1x128)
RAID Option |
3X-MS7AB-AC |
|
1-GB RDRAM Memory (4x256)
Option |
3X-MS7AB-BA |
|
1-GB RDRAM Memory (1x256) RAID
Option |
3X-MS7AB-BC |
|
2-GB RDRAM Memory (4x512)
Option |
3X-MS7AB-CA |
|
2-GB RDRAM Memory (1x512) RAID
Option |
3X-MS7AB-CC |
| |
| Step 5 -
Configure Packaging Options |
| Step 5a - System I/O Expansion |
| I/O Configuration Guidelines: |
- Each AlphaServer GS1280 system (Model 8 or 16) requires one I/O Master Building Block
Drawer
- Each AlphaServer GS1280 system Model 8 supports one additional I/O Building Block Drawer
(Master or Expansion)
- Each AlphaServer GS1280 system Model 16 supports three additional I/O Building Block
Drawers (Master or Expansion)
- Each Master I/O Building Block Drawer supports 11 total configurable slots spread over
four buses (ports)
- Each Master I/O Building Block Drawer supports two hard disk drives and includes an
integrated Ultra3 SCSI adapter
- Each I/O Expansion Building Block Drawer supports 12 total configurable slots spread
over four buses (ports)
|
| Master and Expansion I/O
Building Block Drawer slot specifications: |
| Port # |
Slot # |
Maximum Bus Speed |
Signal Voltage |
# of Devices Supported |
| 0 |
1 |
33 MHz |
3.3V |
1 33 MHz PCI |
| 2 |
33 MHz |
5.0V |
1 CCMAB-AA
(Memory Channel) or
1 CIPCA-BA or
2 3X- KZPBA-CC
(NOTE: No mixing of options
within 5V slots) |
| 3 |
33 MHz |
5.0V |
| 1 |
1 |
133 MHz |
3.3V |
2 66 or 33 MHz
PCI or
2 66 MHz PCI-X or
1(1) 133 MHz PCI-X |
| 2 |
133 MHz |
3.3V |
| 2 |
1 |
66 MHz |
3.3V |
6
33 MHz PCI or
3(2) 66 MHz PCI or
2 66 MHz PCI- X |
| 2 |
66 MHz |
3.3V |
| 3 |
66 MHz |
3.3V |
| 4 |
66 MHz |
3.3V |
| 5 |
66 MHz |
3.3V |
| 6 |
66 MHz |
3.3V |
| 3 |
1 |
2X AGP |
1.5V |
1 1X or 2X AGP |
NOTE: (1)
Two 133 MHz PCI-X devices are supported in Port 1, slots 1 and 2; they will however
operate at 100 MHz.
(2) Five 66 MHz PCI devices are supported in Port 2, slots 1-5; they will however operate
at 50 MHz. |
Modules designed for 5.0V
signaling and 33-MHz bus speed can only operate in Port 0 slots 2 and 3
(reserved for Memory Channel or CIPCA)
Modules designed for 3.3V signaling and 66-MHz bus speed cannot operate in Port 0
slots 2 and 3 |
| Universal PCI modules capable of
operating at 66 MHz will operate at 33 MHz when placed in a 33-MHz slot |
| |
- Mandatory
selection of at least one I/O Master Drawer required per GS1280 system
|
|
- Model 8 systems can support a total of two I/O Drawers; Model 16 systems support a total
of four I/O Drawers
|
|
- I/O Master Drawers contain 10 PCI/PCI-X slots and one1 AGP slot; an N+1 redundant power
system; CD-RW drive, and two Ultra3 SCSI hot-plug disk drive bays (disk drives are NOT
included, they must be ordered separately)
|
|
- I/O Expansion Drawers contain 11 PCI/PCI-X slots and one AGP slot; an N+1 redundant
power system
|
|
- I/O Expansion Drawers contain an internal Ultra3 SCSI adapter and a dual USB port
|
|
- I/O Expansion Drawers and Master I/O Drawers are connected to a System Building Block
Drawer utilizing a 3X-BNPSA-04 cable
|
|
|
I/O Master Drawer |
3X-BA70A-AA |
|
I/O Expansion Drawer |
3X-BA70A-BA |
|
I/O cable for connection between
System Building Block Drawer and I/O Drawer mounted in system power cabinet or expansion
cabinet; one is mandatory per I/O Drawer |
3X-BNPSA-04 |
| |
| Step
5b - Select System Disk |
- Selection of at least one system disk drive is mandatory for each GS1280 system
ordered
|
- Each Master I/O Drawer supports up to two internal hard disk
drives. NOTE: Integrated Ultra3
SCSI controller for internal disk drives and cabling included with each Master I/O Drawer.
|
|
36.4-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3838-AA |
|
72.8-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3839-AA |
|
146-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3841-AA |
|
18.2-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3848-AA |
|
36.4-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3849-AA |
|
72.8-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3851-AA |
| |
| Step 6 -
Internal System Expansion |
- AlphaServer GS1280 Model 8 and Model 16 can support optional configurations shown below
|
|

|
| |
| Step 7 -
Power Distribution Units |
|
- Power supplies included with Model 8 and Model 16 systems can support all combinations
of CPUs, memory, and I/O that can be configured within the system boxes and include N+1
power redundancy
|
|
|
- Mandatory
selection of one 30A or 32A Power Distribution Unit (AC power option)
required for each GS1280 Model 8 system ordered
|
|
|
- Mandatory selection of two 30A or 32A Power
Distribution Units (AC power option) required for each GS1280 Model 16 system ordered
(does not provide dual AC functionality)
|
|
|
120/208V Y or 200V, 30A NEMA
L21-30P plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AA |
|
380/415V Y, IEC 309 32A
6h/230/400~ plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AB |
| |
| Step 8-
External Cabinet Expansion |
|
- Additional I/O Expansion Drawers and StorageWorks Shelves
can be installed in optional 3X-H9A45-ZA Expansion Cabinets.
|
|
|
- 3X-H9A45-ZA Expansion Cabinets can be configured to hold alI
I/O Expansion Drawers (up to three for a Model 16 system); all StorageWorks Model 4314R
and 4354R Shelves (up to 12); or combination of StorageWorks Shelves and I/O Expansion
Drawers.
|
|
|
- Mandatory
selection of one Power Distribution Unit (AC power option) required per
cabinet selected
|
|
|
External Expansion
Cabinet |
3X-H9A45-ZA |
|
120/208V Y or 200V,
NEMA L21-30P plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AA |
|
380/415V Y, IEC 309
32A 6h/230/400~ plug 3 x C19 outlets plus 24 x C13 outlets |
3X-H7606-AB |
| |
|
|

|
| |
| Step 9 - Storage
Adapters/Controllers |
| |
Maximum
# Supported |
|
| Tru64
UNIX |
OpenVMS |
Per
Model 8 System |
Per
Model 16 System |
Per
External I/O Drawer |
Per
Model 8 System |
Per
Model 16 System |
Per
External I/O Drawer |
Speed |
PCI/
PCI-
X Slot |
|
| SCSI -- NOTE: Maximum storage controllers per systems,
all types - Tru64 UNIX: 32, OpenVMS: 26 |
| PCI 2-port Ultra3 (LVD) SCSI
adapter, 64-bit/66-MHz dual-channel (uses one PCI slot); includes internal 68-pin and
external 68-pin VHDCI connectors; requires 3X-BC56J-xx cable to connect adapter to
DS-SL13R-Bx shelf; HSZxx RAID controllers not supported. No shared SCSI or tape support,
no SDLT tape support. No support for Model 4314R single-bus shelves with 3X-KZPEA-DB
adapter. Tru64 UNIX requires graphics adapter to run console utilities (RUN BIOS). |
12 |
24 |
6 |
6 |
12 |
6 |
66 MHz |
3.3V PCI |
3X-KZPEA-DB |
| PCI 1-port Ultra2 (LVD) SCSI
adapter, 32-bit/33-MHz, single-channel (uses one PCI slot); includes internal 68-pin and
external 68-pin HD connectors; order BN38C-xx cable to connect adapter to Ultra3 shelf, or
order VHDCI converter (BN38E-0B) for use with included cable; HSZxx RAID controllers not
supported. No support for shared SCSI. |
8 |
8 |
8 |
8 |
8 |
8 |
33 MHz |
3.3V PCI |
3X-KZPCA-AA |
Ultra160 cable, VHDCI to VHDCI
(341174-B21 6-feet, 341175-B21 12-feet, 164604-B21 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
|
3X-BC56J-xx |
PCI 1-port UltraSCSI wide
differential 32-bit/33-MHz PCI adapter (uses one PCI slot); includes external
68-pin HD connector, requires BN38C-xx cable (2 to 25 meters) to connect adapter to
differential UltraSCSI shelf or RAID controller |
4 |
8 |
2 |
4 |
8 |
2 |
33 MHz |
5V PCI |
3X-KZPBA-CC |
68-pin HD male-to-VHDCI male
UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters |
|
BN38C-xx |
| |
| RAID |
| Ultra160 2-channel internal RAID
controller with 128-MB cache. NOTE:
One controller supported per bus segment; supported only as a data device. |
- |
- |
- |
1 |
1 |
1 |
66 MHz |
3.3V PCI |
3X-KZPDC-BE |
| Ultra160 4-channel internal RAID
controller with 256-MB cache. NOTE:One
controller supported per bus segment; supported only as a data device. |
- |
- |
- |
1 |
1 |
1 |
66 MHz |
3.3V PCI |
3X-KZPDC-DF |
Ultra160 cable, VHDCI to VHDCI
(341174-B21 6-feet, 341175-B21 12-feet, 164604-B21 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet) |
|
3X-BC56J-XX |
| |
| Fibre Channel |
| PCI to 2-Gb Fibre Channel
adapter, 64-bit/66-MHz, single-channel |
16 |
32 |
8 |
15 |
26 |
8 |
66 MHz |
3.3V PCI |
DS-KGPSA-DA |
Fibre Channel cable (BNGBX-xx)
xx=02, 03, 05, 10, 15, 30, 50 meters |
|
BNGBX-xx |
| |
| CIPCA |
PCI CI adapter, requires two PCI
slots
Each PCI CI adapter ordered requires the mandatory selection of an I/O Expansion
Drawer (see Step 6) |
NA |
NA |
NA |
2 |
4 |
1 |
33 MHz |
5V PCI |
CIPCA-BA |
| Computer interconnect cable set,
connects CIPCA to star coupler; select length xx=10, 20, 45 meters |
|
BNCIA-xx |
| |
| Step 10 -
StorageWorks Universal Shelves |
| StorageWorks Model
4314R and Model 4354R Universal Drive Shelves |
| StorageWorks Model 4314R and
4354R Ultra3 SCSI (LVD) single-bus and split-bus Universal drive shelves; refer to
StorageWorks Enclosure 4300 Family QuickSpecs when configuring shelves. When selecting a
DS-SL13R-Bx split-bus shelf, two SCSI channels are required. No support for Model 4314R or
4314T single-bus shelves with 3X-KZPEA-DB adapter. Note that the depth of a DS-SL13R-xx
shelf does not allow front and rear mounting. NOTE:
DS-SL13R single-bus shelves include one 12-foot VHDCI to VHDCI SCSI cable; dual-bus
shelves include two 12-foot VHDCI TO VHDCI SCSI cables. |
|
StorageWorks Model 4314R Ultra3
SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply. No
support for Model 4314R single-bus shelves with embedded Ultra3 SCSI adapter or
3X-KZPEA-DB adapter |
DS-SL13R-AA |
|
StorageWorks Model 4314R Ultra3
SCSI (LVD) single-bus Universal drive rackmount shelf, includes one power supply. No
support for Model 4314R single-bus shelves with embedded Ultra3 SCSI adapter or
3X-KZPEA-DB adapter |
DS-SL13R-AJ |
|
StorageWorks Model 4354R Ultra3
SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power
supplies, U.S. |
DS-SL13R-BA
|
|
StorageWorks Model 4354R Ultra3
SCSI (LVD) split-bus Universal drive rackmount shelf, includes two redundant power
supplies, Japan |
DS-SL13R-BJ
|
| |
| Disk Drives (Supported
in Model 4314R and 4354R Universal Drive Enclosures) |
|
36.4-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3838-AA |
|
72.8-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3839-AA |
|
146-GB Ultra320 SCSI 10,000 rpm
1-inch Universal disk drive |
3R-A3841-AA |
|
18.2-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3848-AA |
|
36.4-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3849-AA |
|
72.8-GB Ultra320 SCSI 15,000 rpm
1-inch Universal disk drive |
3R-A3851-AA |
| |
| Step 11 -
Storage Options |
| Step 11a
Tape Devices |
| AIT Hot-plug Tape
Drives (for use in StorageWorks Model 4314R and 4354R Universal Drive Shelves) |
- AIT hot-plug tape drives require two Universal slots
|
|
| AIT 35/70-GB hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2396-AA |
| AIT 50/100-GB hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2779-AA |
| |
| AIT
Autoloaders |
AIT 35-GB rackmount
autoloader, 8 cartridge, U.S. |
280349-001 |
| Same as above, International |
280349-B31 |
| AIT rail kit for rackmount
autoloader |
284930-001 |
| |
| AIT Tape Libraries |
SSL2020 AIT rackmount library
with one AIT 50-GB drive and 20 slots, LVD |
175196-B21 |
| SSL2020 AIT rackmount library
with two AIT 50-GB drives and 20 slots, LVD |
175196-B22 |
| |
| DAT Hot-plug Tape Drive |
DAT 20/40-GB DDS4 hot-plug LVD
Universal tape drive, uses two slots in 43xxx shelves |
3R-A2780-AA |
| |
| DLT/SDLT Tape
Libraries |
| MSL5026DLX, DLT rackmount library
with 1 40/80-GB DLT tape drive, LVD |
231891-B21 |
| MSL5026DLX, DLT rackmount library
with 2 40/80-GB DLT tape drives, LVD |
231891-B22 |
| MSL5026SL, SDLT rackmount library
with 1 110/220-GB SDLT tape drive, LVD; graphite |
302512-B21 |
| MSL5026SL, SDLT rackmount library
with 2 110/220-GB SDLT tape drives, LVD; graphite |
302512-B22 |
|
MSL5026S2, SDLT
rackmount library with 0 drives, LVD; graphite |
293472-B21 |
| MSL5026S2, SDLT
rackmount library with 1 160/220-GB SDLT tape drive, LVD; graphite |
293472-B22 |
| MSL5026S2, SDLT
rackmount library with 1 160/220-GB SDLT tape drive, LVD; graphite |
293472-B23 |
| MSL5026S2, SDLT
rackmount library with 1 160/220-GB SDLT tape drive, Fibre Channel Interface; graphite |
293472-B24 |
| MSL5026S2, SDLT
rackmount library with 2 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite |
293472-B25 |
|
|
| MSL5000 SDLT2 upgrade
drive, all |
293475-B21 |
| MSL5052SL SDLT
rackmount library, 0 drives, LVD |
255102-B21 |
| MSL5052SL SDLT
rackmount library with 2 110/220-GB drives, LVD |
249491-B21 |
| MSL5052SL SDLT
110/220-GB drive field upgrade, LVD |
231823-B22 |
| MSL5052S2, SDLT
rackmount library with 2 160/220-GB SDLT tape drives, LVD; graphite |
293474-B21 |
| MSL5052S2, SDLT
rackmount library with 2 160/220-GB SDLT tape drives, Fibre Channel Interface; graphite |
293474-B24 |
|
|
| ESL9322S2 SDLT tape
library, with 2 160/320-GB SDLT tape drives, 222 slots -
requires 3X-KZPCA-AA adapter |
293409-B22 |
| ESL9322S2 SDLT tape
library, with 8 160/320-GB SDLT tape drives, 222 slots -
requires 3X-KZPCA-AA adapter |
293409-B28 |
| ESL9322S2 SDLT tape
library, with 2 160/320-GB SDLT tape drives, 322 slots -
requires 3X-KZPCA-AA adapter |
293410-B22 |
| ESL9322S2 SDLT tape
library, with 8 160/320-GB SDLT tape drives, 322 slots -
requires 3X-KZPCA-AA adapter |
293410-B28 |
| |
|
| ESL9000 SDLT2 LVD
Upgrade Drive |
293414-B21 |
| ESL9595SL SDLT tape
library, 0 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B21 |
| ESL9595SL SDLT tape
library, 2 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B22 |
| ESL9595SL SDLT tape
library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter |
274672-B28 |
| ESL9595SL SDLT tape
library, 0 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B21 |
| ESL9595SL SDLT tape
library, 2 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B22 |
| ESL9595SL SDLT tape
library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter |
281627-B28 |
| ESL9595SL SDLT tape
library, 0 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B21 |
| ESL9595SL SDLT tape
library, 2 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B22 |
| ESL9595SL SDLT tape
library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter |
281628-B28 |
| |
|
| ESL9595S2 SDLT2 tape
library, 2 drives, 400 slots - requires 3X-KZPCA-AA adapter |
293411-B22 |
| ESL9595S2 SDLT2 tape
library, 16 drives, 400 slots - requires 3X-KZPCA-AA adapter |
293411-B28 |
| ESL9595S2 SDLT2 tape
library, 2 drives, 500 slots - requires 3X-KZPCA-AA adapter |
293412-B22 |
| ESL9595S2 SDLT2 tape
library, 16 drives, 500 slots - requires 3X-KZPCA-AA adapter |
293412-B28 |
| ESL9595S2 SDLT2 tape
library, 2 drives, 595 slots - requires 3X-KZPCA-AA adapter |
293413-B22 |
| ESL9595S2 SDLT2 tape
library, 16 drives, 595 slots - requires 3X-KZPCA-AA adapter |
293413-B28 |
| ESL9000 SDLT2 LVD
upgrade drive |
293414-B21 |
| |
| 3U Rackmount Tape
Drive Enclosure |
NOTE: The 3U Tape Drive Enclosure supports up to four internal
half-height removable devices, or up to two full height devices. Select up to four AIT or
DAT devices, or two DLT/SDLT devices with 3U Rackmount Tape Drive Enclosure (274338-B21),
or select preconfigured configurations listed below. |
| AIT 35/70-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
216884-B21 |
| AIT 50/100-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
3R-A3753-AA |
| DAT 20/40-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
3R-A3752-AA |
| DLT8000 40/80-GB tape
drive, requires 3X-KZPCA-AA LVD adapter |
146196-B22 |
| SDLT 110/220-GB tape
drive, requires 3X-KZPCA-AA LVD adapter |
192106-B25 |
| SDLT 160/320-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21 |
| Preconfigured
configurations |
| AIT 50-GB 3U
rackmount kit, carbon black |
274333-B21 |
| DLT 40/80-GB, 3U
rackmount kit, carbon black |
274332-B21 |
| DLT 40/80-GB,
dual-drive, 3U rackmount kit, carbon black |
274335-B21 |
| SDLT 110/220-GB, 3U
rackmount kit, carbon black |
274331-B21 |
| SDLT 110/220-GB,
dual-drive, 3U rackmount kit, carbon black |
274334-B21 |
| |
| 5U
Rackmount Tape Drive Enclosure |
NOTE: The 5U Rackmount Tape Drive Enclosure supports four
full-height devices; select up to four DLT or SDLT devices with 274339-B21, or select
preconfigured configurations listed below |
| DLT8000 40/80-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
146196-B22 |
| SDLT 110/220-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
192106-B25 |
| SDLT 160/320-GB tape
drive, requires 3X-KZPCA-AA LVD adapter, carbon black |
257319-B21 |
| Preconfigured
configurations |
| SDLT 110/220-GB Tape
Array III, 5U rackmount kit, carbon black |
274336-B21 |
| DLT 40/80-GB Tape
Array III, 5U rackmount kit, carbon black |
274337-B21 |
| DLT Tape Array III
Model 0 enclosure, U.S. |
168047-001 |
| Same as above,
International |
168047-B31 |
| Same as above, Japan |
168047-291 |
| |
| Step
11b hp StorageWorks Network Storage Routers |
|
1 Fibre Channel x 2 HVD data
router |
3R-A2673-AA |
|
1 Fibre Channel x 2 LVD data
router |
3R-A2774-AA |
|
2 x 4 LVD Fiber Channel to SCSI
Network Storage Router |
3R-A3740-AA |
|
2 x 4 HVD Fiber Channel to SCSI
Network Storage Router |
3R-A3741-AA |
| |
|
|
| Step
11c External Storage Solutions/Controllers |
|
41U graphite storage cabinet,
M3220 Controller assembly with dual HSV110 controllers, 6 M5214 dual FC loop 14-bay drive
enclosures, 4 FC loop switches;
Model 2C6D-B, 60 Hz |
DS-SV110-JA
|
|
41U graphite storage cabinet,
M3220 Controller assembly with dual HSV110 controllers, 6 M5214 dual FC loop 14-bay drive
enclosures, 4 FC loop switches;
Model 2C6D-B, 50 Hz |
DS-SV110-JB
|
|
41U graphite storage cabinet,
M3220 Controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive
enclosures, 4 FC loop switches;
Model 2C12D-B, 60 Hz |
DS-SV110-KA
|
|
41U graphite storage cabinet,
M3220 Controller assembly with dual HSV110 controllers, 12 M5214 dual FC loop 14-bay drive
enclosures, 4 FC loop switches;
Model 2C12D-B, 50 Hz |
DS-SV110-KB
|
| |
|
Fibre Channel Controller (HSG80),
includes 256-MB cache, requires following firmware:
8.6-4F ACS FW (222318-B22, QB-6BUAA-SD), one per controller
8.6-4S ACS FW (222364-B22, QB-6ENAA-SC), one per controller
8.6-4P ACS FW (222316-B22, QB-6CAAA-SD), one per controller
Requires Tru64 UNIX software: 222320-B23, QB-65RAB-SE, one per controller
Requires OpenVMS software: 222321-B22, QB-65RAC-SD, one per controller |
DS-HSG80-BK |
|
Additional 256-MB cache for HSG80 |
DS-HSDIM-AC |
|
Single cache battery, one per
HSG80 controller |
DS-SE2CS-CB |
|
Model 2200 controller shelf for
HSG80 controller - only supported in 9000 Series and M-Series Cabinets |
DS-SE2ZS-C8 |
|
| Step
11d Fibre Channel Options |
|
The following disk drives, hubs,
data routers, switches, and cables are used in Fibre Channel configurations using the
DS-KGPSA-xx adapter. |
|
| Fibre Channel Disk Drives |
36-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4 mm) drive |
3R-A3239-AA |
|
36-GB 15K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4 mm) drive |
3R-A3210-AA |
|
72-GB 10K rpm dual-port 2-Gb/sec
FC-AL 1-inch (25.4 mm) drive |
3R-A3260-AA |
| |
|
|
| Fibre Channel Hubs |
Fibre Channel 7-port Storage Hub,
International (Tru64 UNIX only) |
DS-SWXHB-I7 |
|
Fibre Channel 7-port Storage Hub,
North America (Tru64 UNIX only) |
DS-SWXHB-07 |
|
Fibre Channel 7-port Storage Hub,
Japan (Tru64 UNIX only) |
DS-SWXHB-J7 |
| |
|
|
| Fibre Channel Data Routers |
1 Fibre Channel x 2 HVD data
router |
3R-A2673-AA |
|
1 Fibre Channel x 2 LVD data
router |
3R-A2774-AA |
|
2 x 4 LVD Fiber Channel to SCSI
Network Storage Router |
3R-A3740-AA |
|
2 x 4 HVD Fiber Channel to SCSI
Network Storage Router |
3R-A3741-AA |
| |
|
|
| Fibre Channel Switches |
Fibre Channel 2-Gb 8-port SAN
switch |
DS-DSGGD-AC |
|
Fibre Channel 2-Gb 16-port SAN
switch |
DS-DSGGD-AD |
|
Fibre Channel 2-Gb SAN switch
16-port; |
DS-DSGGD-BA |
|
Fibre Channel 2-Gb 64-port Core
Switch |
DS-DSGGE-AB |
| |
| McData 64-port
Fibre Channel Director/Edge Class Switches |
SAN Director 64 (2 Gb) 32 ports,
base model |
DS-DMGGD-BA |
| SAN Director 64 Long-wave 4-port
module kit |
DS-DMGGD-AC |
|
SAN Director 64 Short-wave 4-port
module kit |
DS-DMGGD-AD |
|
SAN Director 64 Combo, Long
1 port/Short 3 ports - Wave Module Kit |
DS-DMGGD-AE |
|
HP StorageWorks Edge Switch 2/16 |
DS-DMGGE-BB |
|
HP StorageWorks Edge Switch 2/32 |
DS-DMGGE-BC |
|
2-Gb SFF-SW Trncvr Kit |
3R-A2973-AA |
|
NOTE:
Connection for, or between, 1-Gb and/or 2-Gb SAN switches requires different cables. Refer
to the Switches, Hubs, and Interconnects QuickSpecs at: http://www.compaq.com/products/
quickspecs/North_America/10490.html
|
|
| |
| Fibre Channel Cables |
NOTE:
The following LC-SC connector cables support connectivity between 1-Gb and 2-Gb
devices. |
|
2-meter LC-SC multi-mode Fibre
Channel cable |
3R-A2976-AA |
|
5-meter LC-SC multi-mode Fibre
Channel cable |
3R-A2977-AA |
|
15-meter LC-SC multi-mode Fibre
Channel cable |
3R-A2978-AA |
|
NOTE:
The following LC-LC connector cables support connectivity between 2-Gb and 2-Gb
devices. |
|
2-meter LC-LC multi-mode Fibre
Channel cable |
3R-A2979-AA |
|
5-meter LC-LC multi-mode Fibre
Channel cable |
3R-A2980-AA |
|
15-meter LC-LC multi-mode Fibre
Channel cable |
3R-A2981-AA |
| |
| Step 12a - Networks and Communications Mandatory |
- Mandatory
selection of at least one of the following Ethernet adapters is required
for each GS1280 system ordered
- Maximum network adapters supported per system, all types Tru64 UNIX: 16, OpenVMS:
16
|
| |
Maximum
# Supported |
|
Tru64
UNIX |
OpenVMS |
Per
Model 8
System |
Per
Model 16
System |
Per
External I/O Drawer |
Per
Model 8
System |
Per
Model 16
System |
Per External
I/O Drawer |
| Speed |
PCI/
PCI-
X Slot |
|
| Ethernet Adapters |
PCI (32/64-bit, 33-MHz to 66-MHz)
dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or 3X-DE602-FA
optional add-on daughter card can be combined with this module.)
NOTE: Use BN25G, BN26M, BN24Q, or BN28Q
twisted pair RJ45 cables. |
8 |
8 |
8 |
8 |
8 |
8 |
66 MHz |
3.3/
5V |
3X-DE602-BB |
PCI-X/PCI Single-port 10/100/1000
Mbps (Twisted-Pair Copper with RJ45) Gigabit Ethernet NIC.
Cables - BN25G, BN26M, BN24Q, BN28Q, or equivalent with RJ45 connectors.
NOTE: Only supported in PCI mode.
Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required:
EV7 Tima: DEC-AXPVMS
VMS731
_EV7-V0100--
4.PCSI
LAN Tima: DEC-AXPVMS
-VMS731
_LAN-V0100--
4.PCSI |
8 |
8 |
8 |
8 |
8 |
8 |
66 MHz |
3.3V |
3X-DEGXA-TA |
| |
| Step 12b - Networks and Communications - Optional |
| Ethernet Adapters |
Dual-port 10/100 Ethernet
(UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined
3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI
slot option.
NOTE: 3X-DE602-TA cannot
be used standalone.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables. |
8 |
8 |
8 |
8 |
8 |
8 |
33 MHz |
3.3/
5V |
3X-DE602-TA |
Single-port 100 Mbps (MMF/duplex-SC)
add-on daughter card for use with the 3X-DE602-BB. The combined
3X-DE602-BB and 3X-DE602-FA provides two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC)
ports in a single PCI slot option.
NOTE: 3X-DE602-FA cannot be used
standalone. Use BN34A or BN34B cables. |
8 |
8 |
8 |
8 |
8 |
8 |
33 MHz |
3.3/< | |