 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) QuickSpecs

hp AlphaServer ES47 Tower
hp AlphaStation ES47 Tower

spacerw.gif (802 bytes)  

 

11508_OV.gif (48089 bytes)
spacerw.gif (802 bytes)  

At A Glance
AlphaServer?/font> /AlphaStation ?/font> ES47 Tower systems

  • Two 1000-MHz Alpha 21364 processors
  • Advanced on-chip memory controllers and switch logic capable of providing 10.7-GB/s of peak memory bandwidth per processor
  • Choice of memory options; up to 4-GB of RDRAM memory per processor (8-GB total) - Future expansion to 8-GB/processor planned
  • Redundant features providing maximum uptime - N+1 Voltage regulator Modules (VRMs); hot-plug redundant power supplies; cooling provided by four hot-plug redundant system fans
  • Optional RAID memory support
  • Five PCI-X I/O slots
    - One 64-bit/133-MHz slot
    - Four 64-bit/66-MHz slots
  • One AGP slot
  • Internal hot-plug disk drive storage of 292 GB with two 146-GB SCSI disk drives
  • Integrated Ultra3 SCSI
  • CD-RW Drive
  • Dual USB port
  • Enhanced reliability with ECC-protected memory, processor cache and system data paths
  • Tru64 UNIX or OpenVMS factory installed software (FIS); optional high availability support with Tru64 UNIX and OpenVMS cluster solutions
  • Product warranty, 1-year hardware, on-site next business day and 90-day software, telephone support delivered by HP Services
  • Consult the HP Customer Support Center at 1-800 345 1518 for details
contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Standard Features
Processor Two Alpha 21364 1000-MHz CPUs
 
Cache Memory 1.75-MB ECC L2 on-chip cache per CPU
 
Architecture Low-latency, interprocessor (IP) network, with on-chip RDRAM memory controllers and on-chip L2 cache
 
CPUs, Memory, and I/O slots CPUs supported 2
Memory supported Up to 8 GB
PCI-X slots supported 5
AGP slots supported 1
 
Storage Controller Integrated Ultra3 SCSI adapter for internal disk drives
 
Interfaces USB One Dual USB port
Server Mgt One MBM Server Management LAN Connection
Serial One MBM serial connection
 
Form Factor Tower
 
Boot/Diagnostic Devices CD-R Slim line multi-bay 16X/10X/24X CD-RW
Hard Drives Choice of 18.2/36.4/72.8/146-GB SCSI disk drives
 
Internal Disk Expansion Total Internal Drive Bays 2
 
Power Supplies Two @208V (700–Watt @120V) 48V auto-sensing power supplies, hot swappable, N+1 (220v operation only)
 
OS Support AlphaServer ES47Tru64 UNIX Tower systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
AlphaServer ES47 OpenVMS Tower systems include pre-installed software, Base license with System Manager license and Enterprise Integration Server License Package for OpenVMS.
Minimum OS support - Tru64 UNIX V5.1B + IPK or OpenVMS V7.3-1 + VMS731-EV7_V0100 upgrade kit
AlphaStation ES47 Tru64 UNIX Tower systems include pre-installed software, 2-user Base license
AlphaStation ES47 OpenVMS Tower systems include pre-installed software (V7.3-1), Base license, Concurrent Use 1-user license, and NAS 150 Client license
NOTE: For the complete list of supported options, refer to the following Web page: http://h18002.www1.hp.com/alphaserver/options/ases47/
ases47_options.html
 
Service and Support Protected by HP Services including a 1-year on-site hardware warranty Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.
contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) SystemsOptions
Step 1 - Assess Application Requirements
  • Selection of system components must be made in the context of total application requirements. Although the configuration of system components must be done in steps (for example, base system, memories, disks, etc.), these steps should not be done in isolation.
  • The order in which requirements are assessed is also important, since one requirement may impact others. Before proceeding, it would be useful to assess the total application requirements in the following order:
  • What level of availability is required?
  • If no single points of failure are allowed, then the solution should be configured as a multi-system cluster.
  • If access to specific devices must be assured, consider redundant adapters, RAID memory, etc.
  • What overall capacities are required in terms of performance, memory capacity, and disk storage?
  • How should the system be configured to optimize performance?
  • Memory should be configured according to application guidelines listed in Step 4.
  • What are the near-term system expansion needs?
NOTE: Most configuration steps require that the above data be considered in whole or in part. Be sure to execute each step in the context of the total application requirements.
System Ordering Requirements:
Certain system components or services are either required for normal operation or are recommended for best system performance and/or operation. This document uses the following definitions to specify these options:
  • Mandatory purchase: The system cannot function without this option or service - the option or service must be ordered with the system.
  • Required to function: This option or service is needed to support a working system - the option or service must be ordered with the system or be available onsite.
  • Recommended: System performance or function will be enhanced if this option or service is ordered.
AlphaServer/AlphaStation ES47 Tower systems require selection of the following items:
Mandatory Purchases:
  • One Base system (see Step 2)
  • One CPU Building Block Module (see Step 3)
  • One memory option (see Step 4)
  • One system disk drive (see Step 5)
  • Two country-specific power cords (See Step 6)
  • Ethernet adapter (see Step 8)

NOTE: AlphaStation ES47 systems require a graphics adapter (see Step 9)

Optional Purchases:
  • Software media and documentation only required for first system onsite
  • Country-specific keyboard and mouse only if required (see Step 10)
Recommended Services:
  • CarePaq Priority Service Plan
System Management Hardware/Software Requirements
NOTE: The following Server Management requirements only apply to customers who prefer to use the AMS or AMU Server Management software.
  • The AlphaServer Management Station (AMS), provides the highest level of server management for a single or multi platform environment.
    The AMS provides for a local or remote web accessible central point of management and control for a multiple ES47/ES80/GS1280 environment
  • The AlphaServer Management Station (AMS) software requires the following hardware in order to operate:
    - Tru64 UNIX platform with 1-GB memory, 1-GB disk space, and two network interface cards running Tru64 UNIX V5.1B
  • The AlphaServer Management Utility provides the next highest level of server management. The AMU is a GUI based application that provides a sophisticated, yet user-friendly graphics interface to monitor and manage a single ES47/ES80/GS1280 system. From this application, the user can monitor the status of the platform, and provide a significant level of control of the platform. The AMU is a Web based utility, which allows a user local and remote access from a browser.
  • The AlphaServer Management Utility (AMU) requires one of the following hardware platforms in order to operate:
    - Wintel Platform running Windows 2000, 500-MHz CPU or faster, 1-GB memory, 10-GB disk space
    - Tru64 UNIX platform running V5.1B or later, 1-GB memory, 10-GB disk space
  • Both the AMS and AMU Software require Internet Explorer 5 or later or Netscape 6
  
Step 2 - Select Base System
  • Mandatory selection of at least one Base System required

NOTE: Base systems do not include CPUs or memory (see Steps 3 and 4)

AlphaServer ES47 Tower Base Systems
Model OS CPUs Supported
(see Step 3)
I/O Slots Order No.
Tower Tru64 UNIX 2 5 PCI/PCI-X, 1 AGP DA-20AAA-AB
Tower OpenVMS 2 5 PCI/PCI-X, 1 AGP DY-20AAA-AB
AlphaStation ES47 Tower Base Systems
Tower Tru64 UNIX 2 5 PCI/PCI-X, 1 AGP DA-20AAA-AC
Tower OpenVMS 2 5 PCI/PCI-X, 1 AGP DY-20AAA-AC
  
Step 3 - CPU Building Block Modules - Mandatory
  • Mandatory selection of one CPU Building Block Module required per ES47 Tower system
  • CPU Building Block Module includes two 1000-MHz Alpha 21364 CPUs
  • Selection of CPU Building Block Module type (Tru64 UNIX or OpenVMS) must match base system OS selected in Step 2
AlphaServer ES47, Dual CPU Building Block Module, 2xEV7 CPUs, 1000-MHz, Tru64 UNIX SMP License 3X-KN73A-BB
AlphaServer ES47, Dual CPU Building Block Module, 2xEV7 CPUs, 1000-MHz, OpenVMS SMP License 3X-KN73A-BC
contents
 Overview   Standard Features   SystemsOptions   Options   Upgrades   TechSpecs
line.gif (50 bytes)
spacerw.gif (802 bytes) Options
Step 4 - Memory - Mandatory
Memory Configuration Guidelines
Memory options should be selected in the context of the application’s sensitivity to memory bandwidth and future memory capacity expansion. This will determine the number of memory options to order. The total capacity required will determine the size of the options to be ordered.
  • Mandatory selection of at least one memory option required per ES47 tower system.
  • Each ES47 tower system supports up to four memory options (four RIMMs each) and up to four memory RAID options (one RIMM each) for a total of 20 RIMMs.
  • Each CPU has two memory controllers.
  • Each memory controller can support four RIMMs (one memory option) and a fifth RIMM slot for redundancy (RAID option).
  • If populated, the two memory controllers per CPU must contain the same size RIMMs.
  • Order one RAID option (one RIMM) per memory option if desired.
  • If RAID memory option is selected, the number of RAID options selected must equal the number of memory options selected.

The following examples illustrate different ways of configuring an ES47 Tower system with a total of 2 GB of memory

 
   

ES47 Tower System


Case

Memory Option

CPU 1

CPU 2

Controller 1 Controller 2 Controller 1 Controller 2
A 3X-MS7AB-AA (4x128MB) 1 1 1 1
B 3X-MS7AB-BA (4x256MB) 1 - 1 -
C 3X-MS7AB-CA (4x512MB) 1 - - -
 
Memory Application Examples
Configuring memory is a compromise between cost, total memory capacity, and memory bandwidth requirements. The behavior of the application must be used to define the most-desired configuration. Some applications are sensitive to memory capacity while some are sensitive to memory bandwidth. If actual application measurements are not available, the following may be used as guidelines:
  • Large memory (VLM) applications, in which large amounts of memory can substantially reduce I/O throughput, may be optimized for total memory capacity and future capacity growth. In VLM applications, the right balance might be one memory option per CPU. (Case B)
  • Typical commercial applications, such as transaction processing (OLTP) and multi-user timesharing, usually operate efficiently from cache and may not be materially affected by memory bandwidth. Memory configuration is a balance between memory bandwidth and future capacity growth. It is advisable to match the number of memory options to the number of CPUs. (Case B)
  • Data mining can benefit from additional memory bandwidth. In these cases, configure four memory options, two per CPU. (Case A)
  • The most demanding high-performance technical applications (HPTC) achieve a performance level that is directly proportional to memory bandwidth. In these cases, configure four memory options, two per CPU. (Case A)
512-MB RDRAM Memory (4x128) Option

3X-MS7AB-AA

512-MB RDRAM Memory (1x128) RAID Option

3X-MS7AB-AC

1-GB RDRAM Memory (4x256) Option

3X-MS7AB-BA

1-GB RDRAM Memory (1x256) RAID Option

3X-MS7AB-BC

2-GB RDRAM Memory (4x512) Option

3X-MS7AB-CA

2-GB RDRAM Memory (1x512) RAID Option

3X-MS7AB-CC

  
Step 5 - System Disk - Mandatory
  • Mandatory selection of at least one system disk drive is required for each ES47 Tower system ordered. NOTE: Integrated Ultra3 SCSI controller for internal disk drives and cabling included.
  • ES47 Tower systems support up to two internal hard disk drives.
36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3838-AA

72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3839-AA

146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3841-AA

18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3848-AA

36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3849-AA

72.8-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3851-AA

 
Step 6 - Tower Enclosure Power Cords - Mandatory
  • Mandatory selection of two power cords required for each ES47 Tower system ordered
    NOTE: Power supplies included with the Base System
North American,

BN26J-1K

Australia, New Zealand, 2.5-meter

BN19H-2E

Central Europe, 2.5-meter

BN19C-2E

Denmark, 2.5-meter

BN19K-2E

Egypt, India, South Africa, 2.5-meter

BN19S-2E

Israel, 2.5-meter

BN18L-2E

Italy, 2.5-meter

BN35M-02

Japan, 2.5-meter, Dentori approved

3X-BN46F-02

Switzerland, 2.5-meter

BN19E-2E

UK, Ireland, 2.5-meter

BN19A-2E

I/O Configuration Guidelines:
ES47 Tower systems support six total slots spread over three buses (ports). The following table details the internal I/O slots:
Port # Slot # Maximum Bus Speed Signal Voltage Number of Devices Supported
0 1 133 MHz 3.3 V 1 – 133 MHz or 66 MHz PCI-X or
1 – 66 or 33 MHz PCI
1 1 66 MHz 3.3 V 2 – 66 MHz PCI-X or
2 – 66 MHz PCI or
4 – 33 MHz PCI
2 66 MHz 3.3 V
3 66 MHz 3.3 V
4 66 MHz 3.3 V
3 1 2X AGP 1.5 V 1 – 1X or 2X AGP
Step 7- Storage
Step 7a – Storage Adapters/Controllers
  Maximum # Supported  
Tru64 UNIX OpenVMS
  Per System Per System
Speed
PCI/PCI-X Slot  
SCSI          
PCI 2-port Ultra3 (LVD) SCSI adapter, 64-bit/66-MHz dual-channel (uses one PCI slot); includes internal 68-pin and external 68-pin VHDCI connectors; requires 3X-BC56J-xx cable to connect adapter to DS-SL13R-Bx shelf; HSZxx RAID controllers not supported. No shared SCSI or tape support, no SDLT tape support. No support for Model 4314R single-bus shelves with 3X-KZPEA-DB adapter. Tru64 UNIX requires graphics adapter to run console utilities (RUN BIOS). 4 4 66 MHz 3.3V PCI

3X-KZPEA-DB

Ultra160 cable, VHDCI to VHDCI (341174-B21 – 6-feet, 341175-B21 – 12-feet, 164604-B21 – 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet)
 

3X-BC56J-xx

           
PCI 1-port UltraSCSI wide differential 32-bit/33-MHz PCI adapter (uses one PCI slot); includes external 68-pin HD connector, requires BN38C-xx cable (2 to 25 meters) to connect adapter to differential UltraSCSI shelf or RAID controller 4 4 33 MHz 3.3V PCI

3X-KZPBA-CC

68-pin HD male-to-VHDCI male UltraSCSI cable;
xx = 02, 03, 05, 10, 20 meters
 

BN38C-xx

 
RAID
Ultra160 2-channel internal RAID controller with 128-MB cache
NOTE: One controller supported per bus segment; supported only as a data device.
- 1 66 MHz 3.3V PCI

3X-KZPDC-BE

Ultra160 4-channel internal RAID controller with 256-MB cache
NOTE: One controller supported per bus segment; supported only as a data device.
- 1 66 MHz 3.3VPCI

3X-KZPDC-DF

Ultra160 cable, VHDCI to VHDCI (341174-B21 – 6-feet,
341175-B21 – 12-feet, 164604-B21 – 24-feet)
xx = 02 (6-feet), 03 (12-feet), 04 (24-feet)
 

3X-BC56J-XX

 
Fibre Channel
PCI to 2-Gbit Fibre Channel adapter, 64-bit/66-MHz, single-channel 4 4 66 MHz 3.3V PCI

DS-KGPSA-DA

Fibre Channel cable
xx=02, 03, 05, 10, 15, 30, 50 meters
 

BNGBX-xx

 
Step 7b - Storage Expansion – Optional
StorageWorks Model 4314T Standalone Enclosures for Universal Drives Model 4314T Ultra3 SCSI, single-bus tower enclosure, US

DS-SL13T-AA

Model 4314T Ultra3 SCSI, single-bus tower enclosure, International

DS-SL13T-AB

Model 4314T Ultra3 SCSI, single-bus tower enclosure, Japan

DS-SL13T-AJ

NOTE: DS-SL13T enclosures include one 12-foot VHDCI to VHDCI SCSI cable
Universal Disk Drives (Supported in Model 4314T Standalone Enclosures)
36.4-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3838-AA

72.8-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3839-AA

146-GB Ultra320 SCSI 10,000 rpm 1-inch Universal disk drive

3R-A3841-AA

18.2-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3848-AA

36.4-GB Ultra320 SCSI 15,000 rpm 1-inch Universal disk drive

3R-A3849-AA

 
External Tape Storage
AIT Tabletop Tape Drives AIT 35/70-GB 8-mm LVD tabletop tape drive, carbon black, North America; requires LVD adapter

216885-001

Same as above, International

216885-B31

Same as above, Japan

216885-291

AIT 50/100-GB 8-mm SCSI tabletop tape drive with 120V North American power cord, carbon black; requires Ultra2 (LVD) adapter

157767-002

Same as above, International

157767-B32

Same as above, Japan

157767-292

 
AIT Hot-plug Tape Drives (for use in StorageWorks Model 4314T Standalone Enclosures)
  • AIT hot-plug tape drives require two Universal slots
AIT 35/70-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves

3R-A2396-AA

AIT 50/100-GB hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves

3R-A2779-AA

 
AIT Autoloaders AIT 35-GB tabletop autoloader, 8 cartridge, U.S.

292355-001

Same as above, International

292355-B31

 
AIT Tape Libraries SSL2020 AIT tabletop library with one AIT 50-GB drive and 20 slots, LVD

175195-B21

SSL2020 AIT tabletop library with two AIT 50-GB drives and 20 slots, LVD

175195-B22

 
DAT Tabletop Tape Drives DAT 12/24-GB 4-mm narrow single-ended tabletop SCSI tape, includes 120V North American power cord, requires BN31W-xx SCSI cable

DS-TLZ10-DB

DAT 20/40-GB 4-mm Wide Ultra2 (LVD) tabletop SCSI tape drive with 120V North American power cord, carbon black; requires Ultra2 (LVD) adapter

157770-002

Same as above, International

157770-B32

Same as above, Japan

157770-292

 
DAT Hot-plug Tape Drive (for use in StorageWorks Model 4314T Standalone Enclosures) DAT 20/40-GB DDS4 hot-plug LVD Universal tape drive, uses two slots in 43xxx shelves

3R-A2780-AA

 
DAT Autoloaders DAT 20/40-GB auto loader external; requires BN31W-xx SCSI cable and 3X-KZPCA-AA, or 3X-DEPVZ-AA adapter, North America

166505-001

Same as above, International

166505-B31

Same as above, Japan

166505-291

 
DLT/SDLT Tabletop Tape Drives DLT8000 tabletop 40/80-GB DLT external tape drive, carbon black - requires
3X-KZPCA-AA LVD adapter - U.S.

146197-B23

Same as above – Japan

146197-292

SDLT tabletop 110/220-GB external tape drive, carbon black- requires 3X-KZPCA-AA LVD adapter - U.S.

192103-002

Same as above – International

192103-B32

Same as above – Japan

192103-292

SDLT tabletop 160/320-GB external tape drive, carbon black - requires 3X-KZPCA-AA LVD adapter - U.S.

257319-001

Same as above - International

257319-B31

Same as above - Japan

257319-291

 
DLT/SDLT Tape Libraries MSL5026DLX, DLT tabletop library with one 40/80-GB DLT tape drive, LVD

231821-B21

MSL5026DLX, DLT tabletop library with two 40/80-GB DLT tape drives, LVD

231821-B22

MSL5026SL, SDLT tabletop library with one 110/220-GB SDLT tape drive, LVD; graphite

302511-B21

MSL5026SL, SDLT tabletop library with two 110/220-GB SDLT tape drives, LVD; graphite

302511-B22

MSL5026S2, SDLT tabletop library with one 160/320-GB SDLT tape drive, LVD; graphite

293473-B21

MSL5026S2, SDLT tabletop library with two 160/320-GB SDLT tape drives, LVD; graphite

293473-B21

MSL5000 SDLT2 upgrade drive, all

293475-B21

MSL5052SL SDLT 110/220-GB drive field upgrade, LVD

231823-B22

MSL5052S2, SDLT tabletop library with two 160/320-GB SDLT tape drives, LVD; graphite

293476-B21

   
Step 8a - Networks and Communications – Mandatory
  • Mandatory selection of at least one of the following Ethernet adapters is required for each ES47 Tower system ordered
 

Maximum # Supported

   
 

Tru64 UNIX

OpenVMS

   
   Per System Per System Speed PCI/
PCI-X Slot
 
Ethernet Adapters
PCI (32/64-bit, 33-MHz to 66-MHz) dual-port 10/100 Ethernet (UTP/RJ45s) NIC and Base Module. (One 3X-DE602-TA or 3X-DE602-FA optional add-on daughter card can be combined with this module.)
NOTE: Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 66 MHz 3.3/5 V

3X-DE602-BB

PCI-X/PCI Single-port 10/100/1000 Mbps (Twisted-pair Copper with RJ45) Gigabit Ethernet NIC.
Use BN25G, BN26M, BN24Q, BN28Q cables or equivalent w/RJ45 connectors.
NOTE: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required:
EV7 Tima: DEC-AXPVMS–VMS731_EV7-V0100- -4.PCSI
LAN Tima: DEC-AXPVMS-VMS731_LAN-V0100- -4.PCSI
4 4 66 MHz 3.3 V

3X-DEGXA-TA

 
Step 8b - Networks and Communications – Optional
Ethernet Adapters
Dual-port 10/100 Ethernet (UTP/RJ45) add-on daughter card for use with the 3X-DE602-BB only. The combined 3X-DE602-BB and 3X-DE602-TA modules provide four 10/100 (UTP/RJ45s) ports in a single PCI slot option
NOTE: 3X-DE602-TA cannot be used standalone.
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 33 MHz 3.3/5 V

3X-DE602-TA

Single-port 100 Mbps (MMF/duplex-SC) add-on daughter card for use with the 3X-DE602-BB. The combined 3X-DE602-BB and 3X-DE602-FA provides two 10/100 (UTP/RJ45s) and one 100Mbps (MMF/SC) ports in a single PCI slot option.
NOTE: 3X-DE602-FA cannot be used standalone.
Use BN34A or BN34B cables.
4 4 33 MHz 3.3/5 V

3X-DE602-FA

PCI-X/PCI Single-port 1000 Mbps (Fiber with duplex-SC) Gigabit Ethernet NIC.
Use BN34A, BN34B cables or equivalent with SC connectors.
NOTE: Only supported in PCI mode. Supported as a cluster interconnect under OpenVMS only. OpenVMS remedial kit required:
EV7 Tima: DEC-AXPVMS–VMS731_EV7-V0100- -4.PCSI
LAN Tima: DEC-AXPVMS-VMS731_LAN-V0100- -4.PCSI
4 4 66 MHz 3.3 V

3X-DEGXA-SA

 
FDDI Controllers
PCI (32-bit, 33-MHz) to FDDI SAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
4 4 33 MHz 3.3/5 V

3X-DEFPA-AC

PCI (32- bit, 33-MHz) to FDDI DAS (MMF/duplex-SC) NIC
Use BN34A, BN34B, or BN34D cables.
4 4 33 MHz 3.3/5 V

3X-DEFPA-DC

PCI (32-bit, 33-MHz) to FDDI DAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 33 MHz 3.3/5 V

3X-DEFPA-MC

PCI (32-bit, 33-MHz) to FDDI SAS (UTP/RJ45) NIC
Use BN25G, BN26M, BN24Q, or BN28Q twisted pair RJ45 cables.
4 4 33 MHz 3.3/5 V

3X-DEFPA-UC

Multimode fiber optic (MMF) 62.5/125um duplex cable with SC-to-MIC connectors
xx = available lengths: (01, 03, and 10) for 1, 3, and 10 meters
 

BN34D-xx

Synchronous/Asynchronous Controllers
PCI (32-bit, 33-MHz) to Dual-port Intelligent Synchronous Communications NIC -- Requires at least one (maximum two) BN34x sync cable listed below - 2 33 MHz 3.3/5 V

3X-PBXDD-AA

PCI (32-bit, 33-MHz) to Quad-port Intelligent Synchronous Communications NIC -- Requires at least one (maximum four) BN34x sync cable listed below. - 2 33 MHz 3.3/5 V

3X-PBXDD-AB

Synchronous-specific Cables
EIA-530 single-port cable  

3X-BC34G-06

V.24/EIA-232 single-port cable  

3X-BC34L-06

V.11/x.21 single-port cable  

3X-BC33S-06

V.35 single-port cable  

3X-BC34T-06

  
ATM Adapters
PCI (32-bit, 33-MHz) to 155 Mbps ATM, Copper NIC with RJ45 connector
Use BN25G-xx, or BN26M-xx cables.
4 4 33 MHz 3.3/5 V

3X-DAPBA-UA

PCI (32-bit, 33-MHz) to 155 Mbps ATM Fiber NIC with SC connector
Use BN34B-xx cable.
4 4 33 MHz 3.3/5 V

3X-DAPBA-FA

 
Asynchronous Communications
PCI (32-bit, 33-MHz) to 4-port Async Communications NIC with DB-25 octopus cable. 2 2 33 MHz 3.3/5 V

PBXDA-BA

PCI (32-bit, 33-MHz) to 16-port Async Communications Controller and rackmount 16-port distribution box with RJ45 connectors 2 2 33 MHz 3.3/5 V

PBXDA-AC

Asynchronous Connector Adapters
RJ45-to-DB-25 Converter Cable  

CXI01-AC

RJ45-to-DEC MJ11 Converter Cable (8 pack)  

CXI01-AF

Ethernet, FDDI, ATM Cables
Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-ST connectors. xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters  

BN34A-xx

Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-SC connectors. xx = available lengths: (2E, 4E, 01, 03, 10, 20, 30) for 2.4, 4.5, 1, 3, 10, 20, and 30 meters  

BN34B-xx

Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = available lengths: (0B, 0E, 01, 03, 04, 07) for 0.2, 0.5, 1, 3, 4, and 7 meters  

BN25G-xx

Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters  

BN26M-xx

Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters
 

BN24Q-xx

Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity.
xx = available lengths: (0E, 01, 03, 04, 07) for 0.5, 1, 3, 4, and 7 meters
 

BN28Q-xx

 
Step 9 - Graphics – Optional
  • Select graphics adapter, monitor, and country-specific keyboard for Tru64 UNIX and OpenVMS systems if required
 

Maximum # Supported

 
 

Tru64 UNIX

OpenVMS

  Per System Per System Speed PCI/
AGP Slot
 
3Dlabs Oxygen VX1 32-MB PCI 2D graphics accelerator 1 1 66 MHz 3.3V PCI

SN-PBXGF-AB

3Dlabs Oxygen VX1 32-MB AGP 2D graphics accelerator 1 1 4X(1) AGP

SN-PBXGF-BC

ATI Radeon 7500 2D AGP graphics accelerator 1 - 4X(1) AGP

3X-PBXGG-AB

(1) Only supported in 2X mode
Maximum graphics adapters per systems, all types - Tru64 UNIX: 2 (1 AGP and 1 PCI or 2 PCI), OpenVMS: 2 (1 AGP and 1 PCI or 2 PCI)
 
Step 10 - Mouse, Monitors, and Keyboards
Mouse 3-button mouse - USB

3X-PBQWS-WB

PS2 to USB Converter Keyboard and Mouse adapter for USB - allows for connection of a PS2 keyboard and/or mouse to an AlphaServer ES47 Tower System

3R-A4495-AA

  
Monitors
  • Graphics monitors other than those listed can be used if compatible with SVGA graphics ordered with system
  • A video cable, 6-foot/1.8-meter length, is included with all variants of monitors
  • Video extension cable required if monitor is located more than 1-meter from server
  • Monitors will ship with, but not be integrated with systems.
 
Carbon/Silver Monitors V7550 17-inch (16-inch viewable image size) flat-faced shadow mask color monitor, two-tone (carbon/silver), 0.25mm dot pitch, VGA to 1024 x 768 @85 Hz, MPRII/TCO99/
Energy Star compliant, Northern Hemisphere with NA power cord, VGA cable

3R-A4002-AA

Same as above, with Euro power cord

3R-A4201-AA

Same as above, APD, no power cord

3R-A4202-AA

Same as above, with PRC power cord, CCIB

3R-A4446-AA

Same as above, Southern Hemisphere, with Australia/New Zealand power cord

3R-A4203-AA

  
P930 19-inch (18-inch viewable image size) auto-scanning color monitor, Diamondtron NF, 0.24-mm aperture grille pitch, VGA to 1600 x 1200 @85 Hz, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable

3R-A4215-AA

Same as above, with Euro power cord

3R-A4391-AA

Same as above, Taiwan, with NA power cord

3R-A4392-AA

Same as above, with PRC power cord, CCIB

3R-A4394-AA

Same as above, Southern Hemisphere, 0.25 to 0.27 mm aperture grille pitch, with Australia/New Zealand power cord

3R-A4393-AA

 
P1130 21-inch (19.8-inch viewable image size) FD Trinitron auto-scanning color monitor, 0.24-mm aperture grille pitch, VGA to 1792 x 1344 @85Hz, dual video input, USB Hub, MPRII/TCO 99/Energy Star Compliant, Northern Hemisphere with NA power cord, VGA cable

3R-A4216-AA

Same as above, with Euro power cord

3R-A4396-AA

Same as above, Taiwan, no power cord

3R-A4397-AA

Same as above, with PRC power cord, CCIB

3R-A4400-AA

Same as above, Southern Hemisphere, with Australia/New Zealand power cord

3R-A4398-AA

      
Carbon/Silver Flat Panel Monitors TFT1825, 18-inch (18-inch viewable image size) TFT flat panel monitor, 0.28mm pixel pitch, 1600 x 1200 @60Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, one VGA, one DVI-I input connector. NA power cord, VGA and DVI-I cables

3R-A4292-AA

TFT1520, 15-inch (15-inch viewable image size) TFT flat panel monitor, 0.297 mm pixel pitch, 1024 x 768 @75 Hz, multi-mode support, MPRII/TCO99/Energy Star compliant, two video input connectors (one VGA and one DVI-I), NA power cord, VGA and DVI-I cables

3R-A4249-AA

 
Monitor Power Cords North American, 120V, 75-inch

BN26J-1K

Australia, New Zealand, 2.5-meter

BN19H-2E

Central Europe, 2.5-meter

BN19C-2E

Denmark, 2.5-meter

BN19K-2E

Egypt, India, South Africa, 2.5-meter

BN18L-2E

Israel, 2.5-meter

BN19A-2E

Italy, 2.5-meter

BN35M-02

Japan, 2.5-meter, Dentori approved

3X-BN46F-02

Switzerland, 2.5-meter

BN19E-2E

UK, Ireland, 2.5-meter

BN19S-2E

 
Keyboards
USB Keyboard/Language Tru64 UNIX
USB only
OpenVMS
USB and PS/2
U.S./English keyboard 3R-LKQ50-AA 3X-LK463-A2
Arabic keyboard 3R-LKQ50-BR -
Belgian keyboard 3R-LKQ50-AB 3X-LK463-AB
BHCSY keyboard 3R-LKQ50-AX -
Canadian/English keyboard - 3X-LK463-AQ
Canadian/French keyboard 3R-LKQ50-AC 3X-LK463-AC
Cyrillic keyboard (Russian) 3R-LKQ50-BT 3X-LK463-BT
Czech keyboard 3R-LKQ50-BV 3X-LK463-BV
Danish keyboard 3R-LKQ50-AD 3X-LK463-AD
Dutch keyboard 3R-LKQ50-AH 3X-LK463-AH
Finnish keyboard - 3X-LK463-AF
French keyboard 3R-LKQ50-AP 3X-LK463-AP
German keyboard 3R-LKQ50-AG 3X-LK463-AG
Greek keyboard 3R-LKQ50-BH 3X-LK463-BH
Hebrew keyboard 3R-LKQ50-AT 3X-LK463-AT
Hungarian keyboard 3R-LKQ50-BQ 3X-LK463-BQ
International keyboard 3R-LKQ50-BA -
Italian keyboard 3R-LKQ50-AI 3X-LK463-AI
Japanese keyboard 3R-LKQ50-AJ -
Korean keyboard 3R-LKQ50-BK -
Latin-American keyboard 3R-LKQ50-AR -
Norwegian keyboard 3R-LKQ50-AN 3X-LK463-AN
Polish keyboard 3R-LKQ50-BP 3X-LK463-BP
Portuguese keyboard 3R-LKQ50-AV 3X-LK463-AV
Romanian keyboard - 3X-LK463-BL
Simplified Chinese keyboard 3R-LKQ50-CV -
Spanish keyboard 3R-LKQ50-AS 3X-LK463-AS
Swedish keyboard 3R-LKQ50-AM 3X-LK463-AM
Swiss/French keyboard 3R-LKQ50-AK 3X-LK463-AK
Swiss/German keyboard - 3X-LK463-AL
Traditional Chinese keyboard 3R-LKQ50-BI -
Thai keyboard 3R-LKQ50-CB -
Turkish keyboard 3R-LKQ50-BU 3X-LK463-BU
Turkish/F keyboard - 3X-LK463-BW
UK keyboard 3R-LKQ50-AE -
Yugoslavian keyboard - 3X-LK463-BY
 
Step 11 - System Software
Tru64 UNIX
  • Media and documentation required for first system on site
  • Software Processor Code = E
  • Tru64 UNIX base systems include pre-installed software, Base license, Unlimited User license, Server Extension license, Internet Express, and Secure Web Server
Tru64 UNIX media and online documentation on CD-ROM

QA-6ADAA-H8

Tru64 UNIX full hard copy documentation

QA-6ADAA-GZ

TruCluster Plus Software Package with licenses for TruCluster Server, Logical Storage Manager and AdvFS Utilities

QP-6R9AC-AA

TruCluster Server license

QL-6BRAC-AA

Logical Storage Manager license

QL-2GVAE-AA

AdvFS Utilities license

QL-0EGAE-AA

Advanced Server for Tru64 UNIX, 25 client concurrent use license

QL-5U29M-3D

Advanced Server for Tru64 UNIX, 50 client concurrent use license

QL-5U29M-3E

Advanced Server for Tru64 UNIX, 100 client concurrent use license

QL-5U29M-3F

Advanced Server for Tru64 UNIX, 250 client concurrent use license

QL-5U29M-3G

Advanced Server for Tru64 UNIX, 500 client concurrent use license

QL-5U29M-3H

Layered products media and documentation for Tru64 UNIX on CD-ROM

QA-054AA-H8

DECnet/OSI end-system function license for Tru64 UNIX

QL-MTJAE-AA

DECnet/OSI extended license for Tru64 UNIX

QL-MTKAE-AA